aims to streamline the design and construction processes, reducing waste and optimising the supply chain.. 2.

At Bryden Wood, our team utilises CFD analysis from pre-planning to detailed design stages, leveraging its insights to navigate the dynamic nature of site massing and reconcile technical requirements with local regulations.This helps optimise the process and allows architects to test options that may reduce the building footprint and massing..

Felicity McKane (she/her)

External CFD is also a great tool for site-agnostic design.The same design can be tested across a range of weather conditions and orientations, with the risks and benefits of each highlighted.This insight at the early design stage is extremely valuable, for example the impact on plant and building layouts can be optimised when considering the prevailing wind direction..

Felicity McKane (she/her)

It is important to highlight that we don’t only simulate building operation, but also interpret analysis results comprehensively, focusing on the average uplift across all the heat rejection plant, generators and building ventilation intakes rather than solely on the worst-affected equipment.This approach allows us to engage in dialogue with manufacturers to understand how any uplift will affect the performance of the equipment.. With this information, the amount of energy used for cooling can be minimised, reducing both embodied and operational carbon.. Short Break Scenarios.

Felicity McKane (she/her)

Short break scenarios are simulations used to ascertain the behaviour of a data hall during a switch to standby power generation following a failure of mains power, employing transient analysis within Computational Fluid Dynamics (CFD)..

This process has two main components.Analysis of different refurbishment options: from retrofit to new construction.

The question is: which is the correct level of refurbishment to ensure that the embodied carbon benefit outweighs the reduced operational carbon performance?Light refurbishment, retaining as much of the building as possible?

Or a deeper retrofit, which retains only certain structural elements?.Bryden Wood has carried out an operational and embodied carbon analysis on three different levels of intervention on an existing commercial building:.